Helmholz GmbH & Co. KG
About us
<h4>Helmholz - Your expert for PROFINET and industrial networks. </h4>
The broad product spectrum ranges from a decentralized I/O system to switches and repeaters, gateways, an IE bridge/firewall, and secure IoT remote machine access.
Offering the perfect solution for every automation task is Helmholz's claim - through clever, market-driven products as well as uncomplicated, fast and effective support. We are your partner when it comes to well thought-out products for your automation projects.
<b>Innovative and reliable</b>
Innovation power, teamwork and a great sense for quality are the basis to build components smaller and easier and to solve tasks more elegantly. Helmholz customers get to know the very special proximity to the customer of a mid-tier company, that is acting globally yet rooted regionally at the same time.
<b>Countless solutions from a single source</b>
Be it Ethernet and PROFINET switches, NAT and Fieldbus gateways or secure IoT remote access: With contemporary and clever solutions by Helmholz, the high requirements for industrial networks in times of fast-growing automation can be met easily and efficiently – high comfort of use included at all times!
<b>More is more</b>
The highest standards for quality and reliability allow for security in design and during running operations. The complete development and production process of Helmholz products takes place internally or is directed from our company headquarters in Großenseebach in Franconia. Quality management certified according to DIN ISO 9001:2015 accompanies the emergence of each Helmholz product through all phases of the process chain.
<b>www.helmholz.com</b>
Products & services

WALL IE – Industrial NAT Gateway/Firewall
Secure communication and simple addressing – WALL IE protects your automation network against unauthorized access. Due to the individual configuration, the firewall can be easily adapted to the requirements of the respective machine network. The NAT operating mode serves the forwarding of the data traffic between various IPv4 networks. It enables the address translation via NAT and uses packet filters for the limitation of access to the automation network located behind. In the bridge operating mode, WALL IE acts as a layer 2 switch. In contrast with normal switches, however, packet filtering is also possible in this operating mode. This means that the restriction of access to individual areas of your network can be achieved without having to use different networks for this purpose. – Low effort for IP integration in higher-level networks (NAT) – Integration of series machines with the same IP addresses in the production network – NAT (Basic NAT, NAPT und Portforwarding) – SNAT: No adjustment of the network configuration in the LAN network necessary – Access restriction through packet filters: IPV4 addresses, protocol (TCP/UDP/ICMP), ports, MAC addresses – Reduction of the network load through the filtering of broadcasts and multi-casts – Quick and easy configuration via a responsive web interface – Easily integrate same IP subnets through port forwarding (NAPT) – Reduced to the essential functionality – Import and export of the configuration – DHCP-Server (LAN) / DHCP-Client (WAN) – DNS-Server (LAN) – User administration – Space-saving industrial design for DIN rail

PN/EtherNetIP Coupler
With the PN/EtherNetIP Coupler, a simple and uncomplicated connection of a PROFINET machine to an EtherNet/IP machine is possible. The PN/EtherNetIP Coupler allows data transmission between a PROFINET controller and an EtherNet/IP PLC. Received input data on one side of the network are made available as output data on the other side of the network to the PLC. The I/O data exchange takes place live and as fast as possible without further handling blocks. The maximum size of the transferable I/O data is 1024 bytes. Up to 3 input and 3 output assemblies can be configured on the EtherNet/IP network side. Up to 300 slots are available for I/O modules. The integration into the PLC engineering tool is made possible by a GSDML file, an extra configuration software is not necessary. The configuration of the I/O data to be exchanged is performed in the Siemens engineering tool. An EDS file matching the configuration can then be downloaded from the website by the PN/EtherNetIP Coupler and used to configure the EtherNet/IP PLC.

PNModbusTCP Coupler
Simple and uncomplicated connection of a PROFINET network with a ModbusTCP network is possible with the PN/ModbusTCP Coupler. The PN/ModbusTCP Coupler enables data transmission between a PROFINET controller and ModbusTCP participants. Received input data on one of the network sides is made available as output data to the other network side. The IO data transfer takes place live and as quickly as possible without additional handling blocks. The maximum size of the transmitted data is 1024 bytes input/output data. Up to 300 slots for I/O modules are available via which the PROFINET data can be connected to the ModbusTCP coils, inputs and registers as required. The full ModbusTCP address space of 65536 coils, inputs and registers is supported. The integration into the PLC engineering tool is made possible by a GSDML file. In addition to the PROFINET/ModbusTCP communication, the PN/ModbusTCP coupler also provides an MQTT publisher on both network sides. This means that the values exchanged via the gateway can also be distributed to visualization or production data acquisition systems via MQTT.

PN-CAN-Gateway
The PN/CAN gateway CANopen represents a full-featured CANopen master. As a master, the gateway supports network management, SYNC telegrams, nodeguarding/heartbeat for monitoring the nodes and LSS services. Up to 16 PDOs can be configured per CANopen slave. The parameterization of the CANopen nodes via SDO telegrams and the management of emergency messages is also possible. On the PROFINET network, the PN/CAN gateway is a PROFINET I/O device and supports transmission rates of up to 100 Mbit full duplex; on the CAN bus, up to 1 Mbit/s is supported. The I/O data of the CAN nodes are mapped transparently and freely configurable into the PROFINET network and can thus be processed directly in the PLC. The PN/CAN gateway is integrated into the hardware configurator with a GSDML file and can be fully configured there. Further software tools for parameterization, or handling blocks for programming, are not necessary, which makes the use of the gateway uncomplicated. The features MRP (media redundancy) as well as extensive diagnostic functions and an interface for online diagnostics complete the performance characteristics of the PN/CAN gateway.

DP/PN Coupler
Seamless data flow across networks With the new DP/PN Coupler, a simple and uncomplicated connection of PROFIBUS to PROFINET is possible. It allows data transfer between a PROFIBUS master and a PROFINET controller. The maximum size of the transmitted data is 244 bytes of input data and 244 bytes of output data. The DP/PN Coupler is projected via a GSD file on the PROFIBUS side and a GSDML file on the PROFINET side. No additional configuration software is necessary.

PN/PN Coupler
Seamless data flow across networks. With the PN/PN Coupler, a simple and uncomplicated connection of two separate PROFINET networks is possible. The PN/PN Coupler enables data transmission between two PROFINET controllers. A PROFINET IO device is on both PROFINET network sides. Received input data on one of the network sides is made available as output data to the other network side. The IO data transfer takes place live and as quickly as possible without additional handling blocks. The maximum size of the transmitted IO data is 1024 bytes. Up to 16 slots for IO modules of 1 byte and up to 128 bytes are available. The incorporation into the PLC engineering tool is made possible by a GSDML file; special configuration software isn’t necessary.

FLEXtra FLAT Ethernet-Switch, unmanaged, 10/100 Mbps
The Helmholz unmanaged Ethernet switches are suitable for a variety of industrial applications because of their very compact design. The lightweight and tough industrial design is suitable for mounting on a DIN rail and can be easily integrated into your network. Once plugged in, it's ready for use thanks to the simple Plug & Play solution. The tool-free push-in connection for the power supply supports you. The unmanaged Ethernet switch is suitable for PROFINET networks. The LLPD (neighborhood detection) and PTCP (time synchronization) functions are handled correctly with the switch in accordance with the PROFINET standard. The unmanaged Ethernet switch thus complies with PROFINET Conformance Class A. With this variant of the unmanaged Ethernet-Switch, you can connect up to 5 Ethernet participants with 10 or 100 Mbps. If you would like to connect more participants, we recommend our 8-port unmanaged Ethernet Switch. - Store-and-Forward architecture - 10Base-T/100Base-TX - Full-/Half-Duplex - Autonegotiation - Auto MDI/MDI-X (IEEE 802.3u Auto crossover support) - LLDP & PTCP Delay-Traffic blocking (for PROFINET networks) - PROFINET Conformance Class A - QoS-Priority-Queues: 2 per port - 1K MAC address lookup table - 448K bit packet buffering - max forwarding packet length 1552 bytes

FLEXtra FLAT Ethernet-Switch, unmanaged, 8-Port, 10/100Mbps
The Helmholz unmanaged Ethernet switches are suitable for a variety of industrial applications because of their very compact design. The lightweight and tough industrial design is suitable for mounting on a DIN rail and can be easily integrated into your network. Once plugged in, it's ready for use thanks to the simple Plug & Play solution. The tool-free push-in connection for the power supply supports you. The unmanaged Ethernet switch is suitable for PROFINET networks. The LLPD (neighborhood detection) and PTCP (time synchronization) functions are handled correctly with the switch in accordance with the PROFINET standard. The unmanaged Ethernet switch thus complies with PROFINET Conformance Class A. With this variant of the unmanaged Ethernet-Switch, you can connect up to 8 Ethernet participants with 10 or 100 Mbps. If you would like to connect more participants, we recommend our 16-port unmanaged Ethernet Switch.

FLEXtra FLAT Ethernet-Switch, unmanaged, 16-port, 10/100Mbps
The Helmholz unmanaged Ethernet switches are suitable for a variety of industrial applications because of their very compact design. The lightweight and tough industrial design is suitable for mounting on a DIN rail and can be easily integrated into your network. Once plugged in, it's ready for use thanks to the simple Plug & Play solution. The tool-free push-in connection for the power supply supports you. The unmanaged Ethernet switch is suitable for PROFINET networks. The LLPD (neighborhood detection) and PTCP (time synchronization) functions are handled correctly with the switch in accordance with the PROFINET standard. The unmanaged Ethernet switch thus complies with PROFINET Conformance Class A. With this variant of the unmanaged Ethernet-Switch, you can connect up to 16 Ethernet participants with 10 or 100 Mbps.

FLEXtra IP67 Ethernet-Switch, unmanaged, 8-port, 10/100 Mbit
The Helmholz unmanaged Ethernet-Switch IP67 is a very compact switch for a wide range of industrial applications. Thanks to its high IP67 protection class and temperature range from -40 °C to +75 °C, the IP67 unmanaged Ethernet-Switch is ideal for use in rough industrial environments. The product is ideally suited for installation without a control cabinet and therefore offers a wide range of applications. Once plugged in, the simple Plug & Play solution makes it immediately ready for use. The unmanaged Ethernet switch is suitable for PROFINET networks. The LLPD (neighborhood detection) and PTCP (time synchronization) functions are handled correctly with the switch in accordance with the PROFINET standard. The unmanaged Ethernet switch thus corresponds to PROFINET Conformance Class A. With this variant of the unmanaged Ethernet switch you can connect up to 8 Ethernet subscribers with 10 or 100 Mbps.

FLEXtra FLAT PROFINET-Switch, managed, 4-port
The managed PROFINET-Switch supports PROFINET according to Conformance Class B and offers transmission security through ring redundancy as an MRP client. One of the most important functions of a PROFINET-Switch is the prioritizing of the PROFINET frame traffic in the machine network. The managed switch can differentiate whether the frame is a web query, an FTP file transmission, a media stream, or a PROFINET frame. In the case of a high transmission load, the important frames can thus be prioritized in order to prevent frame losses. With a GSDML file you can integrate the switch into your automation environment in the usual way. The supported PROFINET protocols, such as LLPD, DCP, or even diagnosis alarms, can be easily configured and administered. Technical advantages when using a PROFINET-Switch: • Prioritizing of PROFINET frames • Assignment of a configuration via the device name • Neighborhood detection • Device exchange without programming device • Ring redundancy • Each port can be activated or deactivated • Diagnostic messages for network problems • Identification and maintenance data With this variant of the managed PROFINET-Switch, you can connect up to 4 network participants while saving time and money. If you would like to connect more participants, we recommend our 8-port managed PROFINET-Switch.

FLEXtra FLAT PROFINET-Switch, managed, 8-Port
The managed PROFINET-Switch supports PROFINET according to Conformance Class B and offers transmission security through ring redundancy as an MRP client. One of the most important functions of a PROFINET-Switch is the prioritizing of the PROFINET frame traffic in the machine network. The managed switch can differentiate whether the frame is a web query, an FTP file transmission, a media stream, or a PROFINET frame. In the case of a high transmission load, the important frames can thus be prioritized in order to prevent frame losses. With a GSDML file you can integrate the switch into your automation environment in the usual way. The supported PROFINET protocols, such as LLPD, DCP, or even diagnosis alarms, can be easily configured and administered. Technical advantages when using a PROFINET-Switch: • Prioritizing of PROFINET frames • Assignment of a configuration via the device name • Neighborhood detection • Device exchange without programming device • Ring redundancy • Each port can be activated or deactivated •Diagnostic messages for network problems • Identification and maintenance data With this variant of the managed PROFINET-Switch, you can connect up to 8 network participants while saving time and money. If you would like to use only one part, we recommend our 4-port managed PROFINET-Switch.

FLEXtra FLAT PROFINET-Switch, managed, 16-Port
The managed PROFINET-Switch supports PROFINET according to Conformance Class B and offers transmission security through ring redundancy as an MRP client. One of the most important functions of a PROFINET-Switch is the prioritizing of the PROFINET frame traffic in the machine network. The managed switch can differentiate whether the frame is a web query, an FTP file transmission, a media stream, or a PROFINET frame. In the case of a high transmission load, the important frames can thus be prioritized in order to prevent frame losses. With a GSDML file you can integrate the switch into your automation environment in the usual way. The supported PROFINET protocols, such as LLPD, DCP, or even diagnosis alarms, can be easily configured and administered. Technical advantages when using a PROFINET-Switch: • Prioritizing of PROFINET frames • Assignment of a configuration via the device name • Neighborhood detection • Device exchange without programming device • Ring redundancy • Each port can be activated or deactivated • Diagnostic messages for network problems • Identification and maintenance data With this variant of the managed PROFINET-Switch, you can connect up to 16 network participants while saving time and money. If you would like to use only one part, we recommend our 4/8-port managed PROFINET-Switches.

FLEXtra IP67 PROFINET-Switch, managed, 8-Port
The managed PROFINET-Switch supports PROFINET according to Conformance Class B and offers transmission security through ring redundancy as an MRP client. One of the most important functions of a PROFINET-Switch is the prioritizing of the PROFINET frame traffic in the machine network. The managed switch can differentiate whether the frame is a web query, an FTP file transmission, a media stream, or a PROFINET frame. In the case of a high transmission load, the important frames can thus be prioritized in order to prevent frame losses. With a GSDML file you can integrate the switch into your automation environment in the usual way. The supported PROFINET protocols, such as LLPD, DCP, or even diagnosis alarms, can be easily configured and administered. With its protection class IP67 and temperature range from -40 °C to +75 °C, the PROFINET Switch 8 Port, IP67 is ideal for use in rough industrial conditions. The product is ideally suited for installation without a control cabinet and therefore offers a wide range of applications. Technical advantages when using a PROFINET-Switch Prioritizing of PROFINET frames Assignment of a configuration via the device name Neighborhood detection Device exchange without programming device Ring redundancy Each port can be activated or deactivated Diagnostic messages for network problems Identification and maintenance data With this variant of the managed PROFINET-Switch, you can connect up to 8 network participants in harsh environments, saving time and money.

REX 100 Industrial Ethernet Router
Ethernet participants, such as PLC control systems, can be reached with the REX 100 industrial routers, irrespective of the manufacturer. Following models are available: - REX 100 WiFi, 3 x LAN (switch)/1 x WAN/1 x WiFi interface - REX 100 3G, 4 x LAN (switch)/1 x 3G modem (UMTS) - REX 100 LTE, 4 x LAN (switch)/1 x LTE modem (EU- & Asia-Version) - REX 100 LTE, 3 x LAN (switch)/1 x WAN/1 x LTE-Modem (EU- & Asia-Version) - REX 100 LTE, 4 x LAN (switch)/1 x LTE modem (North America Version / “NAG“) - REX 100 WiFi, 4 x LAN (switch)/1 x WiFi interface - REX 100 WiFi, 3 x LAN (switch)/1 x WAN/1 x WiFi interface The REX 100 routers are systematically designed to operate in conjunction with the myREX24 V2 portal: All programming and remote maintenance is carried out exclusively through the portal. With the digital inputs, alarms can be sent via the myREX24 V2 portal as SMS and e-mail. The USB host port present in all devices enables the connection of USB devices (e.g. programming port of a drive) via the remote maintenance tunnel (USB-over-IP). The REX 100 WiFi establishes the connection with the myREX 24 V2 portal via WLAN. Additional Ethernet participants can be connected at the router via the integrated 3-port switch. For data transmission, our industrial router uses an encrypted VPN tunnel on the basis of the secure OpenVPN protocol.

REX 200 Industrial Ethernet Router
With the REX 200 industrial routers, Ethernet subscribers, such as PLC controllers, can be achieved regardless of manufacturer. Following models are available: - REX 200 WAN, 4 x LAN (switch)/1 x WAN port - REX 200 LTE, 4 x LAN (switch)/1 x WAN/1 x LTE modem - REX 200 WiFi, 4 x LAN (Switch)/1 x WAN/1 x WiFi interface The REX 200 routers are designed for operation in conjunction with the myREX24 V2 portal: The complete parameterization and remote maintenance is carried out via the portal. In addition to remote maintenance, the REX 200 routers can also read data from the PLC, visualize and generate alarms. For remote maintenance and data transmission, the industrial router uses an encrypted VPN tunnel based on the secure OpenVPN protocol. With the 4 digital inputs, alarms can be sent via SMS and email via the myREX24 V2 Portal. The 2 digital outputs can be system states of the router, e.g. with a lamp on the control cabinet, or can be activated via the portal. The USB host interface available on all devices enables the connection of USB device devices (eg programming interface of a drive) via the remote maintenance tunnel (USB-over-IP). The REX 200 WiFi establishes the connection to the myREX 24 V2 portal via WLAN. Additional Ethernet devices can be connected to the router via the integrated 4-port switch. For data transmission, our industrial router uses an encrypted VPN tunnel based on the secure OpenVPN protocol.

REX 250 Industrial Ethernet Router
With the REX 250 industrial routers, Ethernet subscribers, such as PLC controllers, can be achieved regardless of manufacturer. Following models are available: REX 250 WAN, 4 x LAN (switch)/1 x WAN interface REX 250 3G, 4 x LAN (switch)/1 x WAN/1 x 3G modem (UMTS) REX 250 LTE, 4 x LAN (switch)/1 x WAN/1 x LTE modem The REX 250 routers are designed for operation in conjunction with the myREX24 V2 portal: The complete parameterization and remote maintenance is carried out via the portal. In addition to remote maintenance, the REX 250 routers can also read data from the PLC, visualize and generate alarms. For remote maintenance and data transmission, the industrial router uses an encrypted VPN tunnel based on the secure OpenVPN protocol. The REX 250 routers also enable remote maintenance and data access to PLCs via an MPI / PROFIBUS and via an RS232 interface. With the 4 digital inputs, alarms can be sent via SMS and email via the myREX24 V2 Portal. The 2 digital outputs can change the system states of the router, e.g. with a lamp on the control cabinet, or can be activated via the portal. The USB host interface available on all devices enables the connection of USB device devices (eg programming interface of a drive) via the remote maintenance tunnel (USB-over-IP). The REX 250 WiFi establishes the connection to the myREX 24 V2 portal via WLAN. Additional Ethernet devices can be connected to the router via the integrated 4-port switch. For data transmission, our industrial router uses an encrypted VPN tunnel based on the secure OpenVPN protocol. REX 250 WiFi, 4 x LAN (Switch)/1 x WAN/1 x WiFi interface

TB20 - Distributed I/O system
With the TB20 I/O system you generate efficient and functional added value for a variety of application areas – irrespective of the fieldbus and proven in practice! Three-component module design TB20 I/O modules have three components: a separate front connector, an electronic module, and a base module. A locking mechanism ensures that all modules can be quickly mounted and securely attached on DIN rails while guaranteeing a reliable electrical connection. Likewise, all modules can be easily and quickly removed for maintenance and/or system expansions. Modules are delivered as complete assembled units (i.e., as a single assembly) and can be installed immediately. This makes keeping expenisve special parts in stock obsolete. Ideal handling, achieved with a compact design The system’s ergonomic design makes it easy to handle. Moreover, the space-saving compact dimensions behind it do not take away from the system components’ heavy-duty sturdiness and reliable electrical contacts for industrial applications, which are further complemented by an IP20 protection rating. An optimal systems engineering breadth can be achieved through the use of modules with up to 16 digital or 8 analog channels and digital mix in/out modules. Clear, unique labels The system’s design ensures that each channel will be labeled clearly and uniquely, in a way that can be easily read during operation. This allows direct allocation of the terminal to the respective LED display. The labeling strips are suitable for laser printers. Hot-Swap capability Individual modules can be replaced quickly and easily while the rest of the system keeps running. The hot swap-compatible electronic module helps keep downtimes to a minimum.

S7 Memory Cards for 1200/1500 series
Helmholz memory cards - the smart alternative! The Helmholz memory cards with a capacity of 4 MB / 12 MB / 24 MB and 256 MB, as well as of 2 GB are suitable for use in your 1200/1500 series from Siemens AG. ✓ Immediate cost saving ✓ Easy installation through plug and play ✓ For use in 1200/1500 series ✓ Available directly from stock

S7 Micro Memory Cards for 300 series
Helmholz memory cards – the smart alternative! The Helmholz micro memory cards with a capacity of 64 kByte, 128 kByte, 256 kByte, 512 kByte, as well as 1 MB, 2 MB, 4 MB and 8 MB are suitable for use in the 300 series modules of Siemens AG suitable. ✓ Immediate cost saving ✓ Easy installation through plug and play ✓ For use in 1200/1500 series ✓ Available directly from stock

PN/MQTT Coupler
The MQTT protocol has become established in recent years as a simple transmission protocol for messages in the IoT world. MQTT stands for "Message Queue Telemetry Transport Protocol" and is an OASIS standard. The MQTT protocol always uses a central broker for communication between devices, which receives messages from, for example, a sensor and forwards them to interested devices, such as a control unit. When a sensor sends data to the broker, it is called a "publish". If a device needs data, it must subscribe to the broker ("Subscribe"). The broker delivers the data to all subscribers when new data has arrived from the publisher. With the PN/MQTT Coupler it is possible to transfer values between a PROFINET machine (PLC) and a MQTT broker. It is possible to send values from the PLC via PROFINET to a broker ("Publish") as well as to subscribe values from a MQTT broker and receive them in the PLC via PROFINET ("Subscribe"). The integration into the PLC engineering tool is enabled by a GSDML file, an extra configuration software is not necessary. All settings for the MQTT connection can be done on the web page of the device. MQTT brokers can be connected locally in the own network ("On premise") as well as via the internet in the cloud. Direct integration into the PLC puts full control of the data exchange with the IoT world in the hands of the programmer.

FLEXtra STAGE PROFINET-Switch, managed, 16-Port, 1 GBit
The managed FLEXtra PROFINET switch 16 port can be used to network PROFINET components with 100 Mbps as well as Ethernet nodes with up to 1000 Mbps. Thus, communication from the control level and the machine or the mixing of Ethernet and PROFINET components in one switch is possible. PROFINET prioritization according to Conformance Class B of the machine components is always guaranteed. One of the most important functions of a PROFINET switch is the prioritization of PROFINET telegram traffic in the machine network. The managed switch can distinguish whether the telegram is a web request, an FTP file transfer, a media stream, or a PROFINET telegram. In the event of a high transmission load, the important telegrams can thus be prioritized to prevent telegram losses of the machine components. The supported PROFINET protocols, such as LLDP, DCP or diagnostic alarms, can be easily parameterized and managed. In addition to PROFINET, functions such as SNMP, NTP, VLAN, port mirroring, QoS/CoS mapping and extensive statistics are available for managing the Ethernet network. If required, the configuration can be saved on an SD card or loaded for commissioning. The practical design with the intelligent arrangement of the Ethernet sockets saves space in the control cabinet. The status LEDs on the top of the FLEXtra PROFINET switch, which are always clearly visible, allow for easy diagnostics even when fully wired. In addition, the FLEXtra PROFINET switch supports port control via inputs and port status indication via outputs. Bits in the PROFINET-IO image of the switch can be used as inputs and outputs as well as 4 digital inputs and 2 digital outputs with 24V. The assignment and the function of the inputs and outputs can be configured via the GSDML file.

FLEXtra STAGE Ethernet-Switch, unmanaged, 16-Port, 1 GBit
The new Helmholz FLEXtra Ethernet switch unmanaged for up to 1000 Mbit (Gigabit) can be used for a wide range of industrial applications thanks to its very compact design. The lightweight yet robust industrial design is suitable for DIN rail mounting and is very easy to integrate into your network. Once plugged in, it is immediately ready for operation due to the simple plug & play solution. The tool-free push-in connection for the redundant power supply supports you in this. The practical design with the intelligent arrangement of the Ethernet sockets saves space in the control cabinet. The status LEDs on the top of the FLEXtra Ethernet switch, which are always clearly visible, enable easy diagnostics even when the cabling is full. The FLEXtra Ethernet switch unmanaged is suitable for PROFINET networks. The LLPD (neighbor detection) and PTCP (time synchronization) functions are handled correctly with the switch according to the PROFINET standard. The FLEXtra Ethernet switch unamanged thus complies with PROFINET Conformance Class A. With the FLEXtra Ethernet switch you can connect up to 16 Ethernet nodes with up to 1000 Mbps. Mixed operation with devices that only support 10 or 100 Mbit is possible without configuration effort. – Store-and-forward architecture – 10BASE-T/100BASE-TX/1000BASE-T – Full-/Half-Duplex – Auto negotiation – Auto MDI/MDI-X (IEEE 802.3u auto crossover support) – QoS priority queues: 8 – LLDP & PTCP delay traffic blocking (for PROFINET networks) – PROFINET Conformance Class A – 2x 16K MAC address lookup table – 2x 256 Kbyte memory for frame buffering – Up to 51 Gbps high-performance memory bandwidth – Supports Jumbo frame sizes up to 10KByte – Redundant power supply

TAP IE 100, Ethernet Test Access Point, 10/100 Mbps
The TAP IE 100 enables recording of Ethernet communications at 10 or 100 Mbps without retroactive effect. The Ethernet transmission via the Line RJ45 sockets is sent out on the two monitor sockets as a "copy". With a PC or other diagnostic device the Ethernet telegrams can be logged and analyzed, e.g. with "Wireshark". The practical flat design with the intelligent arrangement of the network connections saves space in the control cabinet. – Non-reactive recording of Ethernet communication – Secure and passive decoupling of telegrams – Monitors all OSI layers starting from layer 2 and mirrors packets of all sizes and types and VLAN traffic – For 10 or 100Mbit/s – No influence on Ethernet transmission in case of power failure

WALL IE PLUS – Industrial NAT Gateway/Firewall
Secure communication and simple addressing – WALL IE PLUS protects your automation network against unauthorized access. Due to the individual configuration, the firewall can be easily adapted to the requirements of the respective machine network. The WALL IE PLUS provides 8 ports with up to 1000 Mbps transfer rate for networking. All 8 ports can be assigned to the WAN or LAN network as desired. The NAT operating mode serves the forwarding of the data traffic between various IPv4 networks. It enables the address translation via NAT and uses packet filters for the limitation of access to the automation network located behind. In the bridge operating mode, WALL IE acts as a layer 2 switch. In contrast with normal switches, however, packet filtering is also possible in this operating mode. This means that the restriction of access to individual areas of your network can be achieved without having to use different networks for this purpose. - 8 ports for 100/1000 Mbps with free assignment to LAN or WAN network - Low effort for IP integration in higher-level networks (NAT) - Integration of series machines with the same IP addresses in the production network - NAT (Basic NAT, NAPT und Portforwarding) - SNAT: No adjustment of the network configuration in the LAN network necessary - Access restriction through packet filters: IPV4 addresses, protocol (TCP/UDP/ICMP), ports, MAC addresses - Reduction of the network load through the filtering of broadcasts and multi-casts - Quick and easy configuration via a responsive web interface - Easily integrate same IP subnets through port forwarding (NAPT) - Reduced to the essential functionality - Import and export of the configuration - DHCP-Server (LAN) / DHCP-Client (WAN) - DNS-Server (LAN) - User administration - Space-saving industrial design for DIN rail

Ethernet Cable Guard
The Cable Guard is looped into the drag chain cable to be monitored and can provide information about the quality of the cable connection via a status LED, a separate network connection or a digital output. The feedback can be displayed as a PWM signal at the output. The alarm threshold value can be set individually. For integration into IIoT structures, the monitored cable status can also be sent via MQTT by the Cable Guard. The particularly compact design is suitable for use in decentralized control cabinets and can be mounted on standard top-hat rails. The Cable Guard is also suitable for EtherCAT, EtherNet/IP and 2-pair PROFINET applications.

FLEXtra SLIM Ethernet-Switch 5-Port, unmanaged, 100 Mbit + 1 Gbit
The switch is suitable for DIN rail mounting and is very easy to integrate into your network. Once plugged in, it is immediately ready for operation thanks to the simple plug & play installation. No configuration is necessary. The 5-port unmanaged Ethernet switch is suitable for PROFINET networks. The LLPD (neighbourhood detection) and PTCP (time synchronisation) functions are handled correctly with the switch in accordance with the PROFINET standard. The unmanaged Ethernet switch therefore complies with PROFINET Conformance Class A. Connect up to 5 Ethernet devices at 10 or 100 Mbit/s or new up to 1 Gbit.

FLEXtra SLIM Ethernet-Switch 8-Port, unmanaged, 10/100 Mbit + 1 Gbit
The switch is suitable for DIN rail mounting and is very easy to integrate into your network. Once plugged in, it is immediately ready for operation thanks to the simple plug & play installation. No configuration is necessary. The 8-port unmanaged Ethernet switch is suitable for PROFINET networks. The LLPD (neighbourhood detection) and PTCP (time synchronisation) functions are handled correctly with the switch in accordance with the PROFINET standard. The unmanaged Ethernet switch therefore complies with PROFINET Conformance Class A. Connect up to 8 Ethernet devices at 10 or 100 Mbit/s or new: 1 Gbit.